Set burst fusion, in percentage of window size. Allowed range is @code{0} to
@code{10}. Default value is @code{2}.
If any two samples detected as noise are spaced less than this value then any
-sample in between those two samples will be also detected as noise.
+sample between those two samples will be also detected as noise.
@item m
Set overlap method.
@end table
@item response
-Show IR frequency reponse, magnitude and phase in additional video stream.
+Show IR frequency response, magnitude and phase in additional video stream.
By default it is disabled.
@item channel
@itemize
@item
-Apply 2 pole elliptic notch at arround 5000Hz for 48000 Hz sample rate:
+Apply 2 pole elliptic notch at around 5000Hz for 48000 Hz sample rate:
@example
aiir=k=1:z=7.957584807809675810E-1 -2.575128568908332300 3.674839853930788710 -2.57512875289799137 7.957586296317130880E-1:p=1 -2.86950072432325953 3.63022088054647218 -2.28075678147272232 6.361362326477423500E-1:f=tf:r=d
@end example
@item r
Set research radius duration. Allowed range is from 2 to 300 milliseconds.
Default value is 6 milliseconds.
+
+@item o
+Set the output mode.
+
+It accepts the following values:
+@table @option
+@item i
+Pass input unchanged.
+
+@item o
+Pass noise filtered out.
+
+@item n
+Pass only noise.
+
+Default value is @var{o}.
+@end table
@end table
@section anull
@item reset
Set number of frame after which stats are going to be recalculated.
Default is disabled.
+
+@item measure_perchannel
+Select the entries which need to be measured per channel. The metadata keys can
+be used as flags, default is @option{all} which measures everything.
+@option{none} disables all per channel measurement.
+
+@item measure_overall
+Select the entries which need to be measured overall. The metadata keys can
+be used as flags, default is @option{all} which measures everything.
+@option{none} disables all overall measurement.
+
@end table
A description of each shown parameter follows:
Set factor to amplify difference. Default is 2. Allowed range is from 0 to 65535.
@item threshold
-Set threshold for difference amplification. Any differrence greater or equal to
+Set threshold for difference amplification. Any difference greater or equal to
this value will not alter source pixel. Default is 10.
Allowed range is from 0 to 65535.
+@item tolerance
+Set tolerance for difference amplification. Any difference lower to
+this value will not alter source pixel. Default is 0.
+Allowed range is from 0 to 65535.
+
@item low
Set lower limit for changing source pixel. Default is 65535. Allowed range is from 0 to 65535.
This option controls maximum possible value that will decrease source pixel value.
@item sigma
Set denoising strength. Default value is 1.
Allowed range is from 0 to 999.9.
-The denoising algorith is very sensitive to sigma, so adjust it
+The denoising algorithm is very sensitive to sigma, so adjust it
according to the source.
@item block
Set horizontal sigma, standard deviation of Gaussian blur. Default is @code{0.5}.
@item steps
-Set number of steps for Gaussian approximation. Defauls is @code{1}.
+Set number of steps for Gaussian approximation. Default is @code{1}.
@item planes
Set which planes to filter. By default all planes are filtered.
@end table
@item color_trc
-Set the color transfert.
+Set the color transfer.
Available values are:
@table @samp
@item acount
Set how much frames to accumulate in histogram.
-Defauls is 1. Setting this to -1 accumulates all frames.
+Default is 1. Setting this to -1 accumulates all frames.
@item rheight
Set histogram ratio of window height.