EBU R128 loudness normalization. Includes both dynamic and linear normalization modes.
Support for both single pass (livestreams, files) and double pass (files) modes.
-This algorithm can target IL, LRA, and maximum true peak. To accurately detect true peaks,
-the audio stream will be upsampled to 192 kHz unless the normalization mode is linear.
+This algorithm can target IL, LRA, and maximum true peak. In dynamic mode, to accurately
+detect true peaks, the audio stream will be upsampled to 192 kHz.
Use the @code{-ar} option or @code{aresample} filter to explicitly set an output sample rate.
The filter accepts the following options:
Range is -99.0 - +99.0. Default is +0.0.
@item linear
-Normalize linearly if possible.
-measured_I, measured_LRA, measured_TP, and measured_thresh must also
-to be specified in order to use this mode.
-Options are true or false. Default is true.
+Normalize by linearly scaling the source audio.
+@code{measured_I}, @code{measured_LRA}, @code{measured_TP},
+and @code{measured_thresh} must all be specified. Target LRA shouldn't
+be lower than source LRA and the change in integrated loudness shouldn't
+result in a true peak which exceeds the target TP. If any of these
+conditions aren't met, normalization mode will revert to @var{dynamic}.
+Options are @code{true} or @code{false}. Default is @code{true}.
@item dual_mono
Treat mono input files as "dual-mono". If a mono file is intended for playback